MESR Modbus Gateways bridge devices on Modbus serial networks (RS-232, RS-422 or RS-485) with those on Modbus TCP networks, allowing seamless integration of any Modbus device. Each serial port is accessible over a LAN or WAN by up to 16 simultaneous Modbus TCP masters. All Vlinx™ MESR gateways feature auto detecting 10/100Base T copper and fiber optic connections.

Simple Installation and Setup

  • Removable terminal blocks simplify power and data connections
  • Slimline IP30 DIN mount enclosure minimizes footprint
  • Simple configuration through the built-in web server, or Windows configuration software
  • Built-in traffic monitor for instant verification of successful installation and simple network diagnostics
  • Optional pass-through Ethernet port eliminates need for additional Ethernet switch port
  • Optional Fiber Optic Ethernet connections for long-distance and total noise immunity
Features Benefits
Slim, Industrial Enclosure Save DIN rail space while maintaining industrial ratings
Modbus Master/Slave Flexibility Modbus master or slave can be on any serial port or on the Ethernet port. Customizable to your application.
Web Server, Configuration Software Program through web browser or local port. Same user interface; no training required
Complete Fiber Options Connect to all fiber networks in your plant without converting to copper connections
Low Latency, High Throughput View status in real time


Ethernet Master Serial Slaves
MESR9xx modules can be used to integrate serial slave devices on a MODBUS TCP network. This allows TCP Masters to control serial slave devices.

Ethernet Master Serial Slaves
Vlinx™ MESR Configuration Screens for this Application

Serial & Ethernet Masters, Serial & Ethernet Slaves
MESR9xx modules can also integrate multiple master devices onto serial and Ethernet networks.

Serial & Ethernet Masters, Serial & Ethernet Slaves
Vlinx™ MESR Configuration Screens for this Application

Two Identical Hard Coded Slaves
In this scenario, two slave devices that are hard coded with the same ID are required. This is accomplished by placing them on different serial ports.

Two Identical Hard Coded Slaves

Serial Masters with IP Slaves
Serial Masters can be used to control IP slaves

Serial Masters with IP Slaves
Vlinx™ MESR Configuration Screens for this Application

Identical Networks
In this scenario, identical or backup production lines can be controlled by the same IP Master. This allows the duplicate networks to be configured identically, saving documentation and maintenance time.

Identical Networks
Vlinx™ MESR Configuration Screens for this Application

Specifications

  • Class 1 Division 2 certified
  • Support for Windows 7 Operating Systems
  • Serial ports work with RS-232, RS-422/485 and are software configurable
  • Modbus RTU or ASCII
  • Supports up to 16 simultaneous Modbus TCP masters
  • Modbus messaging priority control (source or function code selectable)
  • Auto detecting 10/100 Ethernet port
  • Operating Temperature: -34 to 80°C
  • 10 to 48 VDC (58 VDC Maximum) input power
  • Management: Multiple TCP/IP Client Sessions
  • UL Listed
  • NEMA TS2 rated for traffic applications 

Applications and Related Information

Recommended Related Articles

Competitive Comparison Chart

Suggested Application Uses

  • Industrial devices (PLCs, drives, motor controls, process analyzers)
  • OPC server applications
  • PC controllers (Think and Do, Steeplechase) 

Models

photoIconPDFModel No.DescriptionPrice 
MESR901 Modbus Gateway, (1) Serial DB9 or TB, (1) 10/100 Ethernet RJ45 $307.97 Get A High Volume Quote
MESR902T Modbus Gateway, (2) Serial TB, (1) 10/100 Ethernet RJ45 $529.00 Get A High Volume Quote
MESR921 Modbus Gateway, (1) Serial DB9 or TB, (2) 10/100 Ethernet RJ45 $329.00 Get A High Volume Quote
MESR922T Modbus Gateway, (2) Serial TB, (2) 10/100 Ethernet RJ45 $549.00 Get A High Volume Quote
MESR921-MC Modbus Gateway, (1) Serial DB9 or TB, (1) 100BaseFX Multi-Mode SC, (1) 10/100 RJ45 Ethernet $544.87 Get A High Volume Quote
MESR921-MT Modbus Gateway, (1) Serial DB9 or TB, (1) 100BaseFX Multi-Mode ST, (1) 10/100 RJ45 Ethernet $529.00 Get A High Volume Quote
MESR921-SC Modbus Gateway, (1) Serial DB9 or TB, (1) 100BaseLX Single-Mode SC, (1) 10/100 RJ45 Ethernet $529.00 Get A High Volume Quote
MESR921-ST Modbus Gateway, (1) Serial DB9 or TB, (1) 100BaseLX Single-Mode ST, (1) 10/100 RJ45 Ethernet $529.00 Get A High Volume Quote
MESR922T-MC Modbus Gateway, (2) Serial TB, (1) 100BaseFX Multi-Mode SC, (1) 10/100 RJ45 Ethernet $749.00 Get A High Volume Quote
MESR922T-MT Modbus Gateway, (2) Serial TB, (1) 100BaseFX Multi-Mode ST, (1) 10/100 RJ45 Ethernet $749.00 Get A High Volume Quote
MESR922T-SC Modbus Gateway, (2) Serial TB, (1) 100BaseLX Single-Mode SC, (1) 10/100 RJ45 Ethernet $749.00 Get A High Volume Quote

Accessories

 Model No.Product Name and DescriptionPriceQty 
MDR-60-24DIN rail mount power supply 24VDC, 2.5 A output power, slimline$63.00
485HESPRS-485 Surge Protector$112.27
HESP4DRRS-422/485 Dataline Surge Suppressor$101.97
232HESPRS-232 Surge Protector$109.00
422HESPRS-422 Surge Protector$112.27
MODSCAN32ModScan32 Modbus Shareware Software$65.00

Downloads